Skip to content
Log in Create an account

P1442 Leakage Diagnostic Pump Control Circuit Signal Low (Bmw)

Powertrain manufacturer code

Learn more

EGR valve: common causes

  • Carbon fouling is the number one cause: exhaust soot hardens in the valve and its passages, which then stick open or closed.
  • City driving, short trips and long idling speed it up (EGR works mostly at low load); regular road driving reduces it.
  • Oil vapour makes it worse: crankcase ventilation, a turbo using oil, worn rings or valve stem seals, unsuitable oil.
  • On diesels with an EGR cooler: an internal cooler leak causes coolant loss with no visible leak.
  • Also check: position sensor, electrical or vacuum control, MAF and intake pressure sensors.

Sources: www.ms-motorservice.com · car.co.uk · www.ms-motorservice.com

Meaning by manufacturer

Bmw
Leakage Diagnostic Pump Control Circuit Signal Low
Buick, Cadillac, Chevy, Chrysler, Gm, Gmc, Oldsmobile, Plymouth, Pontiac, Saturn
EVAP Vacuum Switch High Voltage During Ignition On
BRPROG solutions :EVAP OFF
Ford, Lincoln, Mercury
Secondary Air Injection System Monitor Circuit High Voltage
Subaru
Fuel Level Sensor Circuit Range Performance
Volkswagen
EGR Valve Position Sensor Signal Too High
BRPROG solutions :EGR OFF

Reading the code

P
Powertrain (engine, transmission, ignition)
1
Manufacturer-specific code: the meaning depends on the make
442
Exact fault detected

OBD-II code structure (SAE J2012 standard): wikipedia.org

Look up another code

Open database (MIT) + BRPROG workshop codes. Indicative information, with no guarantee of completeness or accuracy: it does not replace a vehicle diagnosis.

✕
BRPROG.FR DIGITAL ACCESS
Choose your language
SELECT YOUR LANGUAGE